Plastic
GN 552.6 ATEX-Breather Caps, with/without filter, with/without dipstick

Type
A | Without dipstick |
B* | With dipstick |
Identification no.
1 | With splash guards, without filter |
2 | With splash guards, with PU filter |
d1 | d2 | d3 | d4 | l1 | l2 | l3 |
---|---|---|---|---|---|---|
31 | G 3/8 | 10 | 30 | 9,5 | 29 | 188 |
31 | G 1/2 | 12 | 30 | 9,5 | 29 | 188 |
42 | G 3/4 | 18 | 41 | 11,5 | 35,5 | 184 |
Filter combination produces no result.
** not available from stock, requires a minimum order quantity
Specification
Upper part (cap)
Plastic (Polyamid PA)
Lower part (threaded part)
Plastic (Polyamid PA)
Seal
Rubber NBR (Perbunan®)
Air filter PU-foam (Polyurethane)
Filtration 40 µm
Dipstick
Steel, phosphated
RoHS
Plastic (Polyamid PA)
- Temperature resistant up to 80 °C
- Yellow, RAL 1021, matte finishGB
Lower part (threaded part)
Plastic (Polyamid PA)
- Temperature resistant up to 80 °C
- Black, matte finish
Seal
Rubber NBR (Perbunan®)
Air filter PU-foam (Polyurethane)
Filtration 40 µm
Dipstick
Steel, phosphated
RoHS
On request
Fluid level markings / special lengths
see GN 109
see GN 109
Information
ATEX-Breather caps GN 552.6 are suitable for use in an explosion risk environment. They comply with the guidelines (ATEX) 2014/34/EU.
MAX-MIN markings can easily be marked on the two flat sides of the dipstick (see GN 109).
A detailed operating instruction is available and is included with every breather cap.
Function and operational criteria of breather caps see GN 552.
see also...
How to order |
| ||||||||||
GN 552.6-31-G1/2-A-1-GB |
This could also be interesting...
RoHS compliant:
-

Weight:
-

PDF not available